Part Number Hot Search : 
383AMX1T MH1362P 4732A BSO150N LDS6100 SI5441DC HSM106 MRF897R
Product Description
Full Text Search
 

To Download TISP4015H1BJR-S Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 oH V SC AV ER OM AI SIO PL LA N IA BL S NT E
TISP4015H1BJ, TISP4030H1BJ, TISP4040H1BJ VERY LOW VOLTAGE BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
*R
TISP40xxH1BJ VLV Overvoltage Protector Series
Low Capacitance `4015 ................................................................................... 78 pF `4030 ................................................................................... 62 pF `4040 ................................................................................... 59 pF Digital Line Signal Level Protection -ISDN -xDSL Safety Extra Low Voltage, SELV, values
SMBJ Package (Top View)
R(B) 1
2 T(A)
MDXXBGE
Device `4015 `4030 `4040
VDRM V 8 15 25
V(BO) V 15 30 40
Device Symbol
T
100 A "H" Series specified for: ITU-T recommendations K.20, K.45, K.21 FCC Part 68 and GR-1089-CORE
SD4XAA
R
Terminals T and R correspond to the alternative line designators of A and B
Wave Shape 2/10 s 8/20 s 10/160 s 10/700 s 10/560 s 10/1000 s
Standard GR-1089-CORE IEC 61000-4-5 FCC Part 68 ITU-T K.20/45/21 FCC Part 68 FCC Part 68 GR-1089-CORE
ITSP A 500 400 200 150 125 100
............................................ UL Recognized Components
Description
These devices are designed to limit overvoltages on digital telecommunication lines. Overvoltages are normally caused by a.c. power system or lightning flash disturbances which are induced or conducted on to the telephone line. A single device provides 2-point protection and is typically used for the protection of transformer windings and low voltage electronics. The protector consists of a symmetrical voltage-triggered bidirectional thyristor. Overvoltages are initially clipped by breakdown clamping until the voltage rises to the breakover level, which causes the device to crowbar into a low-voltage on-state condition. This low-voltage on state causes the current resulting from the overvoltage to be safely diverted through the device. The device switches off when the diverted current falls below the holding current value.
How to Order
For Standard For Lead Free Termination Finish Termination Finish Marking Code Std. Qty. Order As Order As TISP 40xxH1BJR-S 40xxH1 3000
Device TISP40xxH1BJ
Package
Carrier
SMB (DO-214AA) Embossed Tape Reeled TISP 40xxH1BJR
Insert xx value corresponding to protection voltages of 15 V, 30 V and 40 V.
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex AUGUST 1999 - REVISED FEBRUARY 2005 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.
TISP40xxH1BJ VLV Overvoltage Protector Series
Absolute Maximum Ratings, TA = 25 C (Unless Otherwise Noted)
Rating Repetitive peak off-state voltage Non-repetitive peak on-state pulse current (see Notes 1 and 2) 2/10 s (Telcordia GR-1089-CORE, 2/10 s voltage wave shape) 8/20 s (I EC 61000-4-5, combination wave generator, 1.2/50 voltage, 8/20 current) 10/160 s (FCC Part 68, 10/160 s voltage wave shape) 5/310 s (I TU-T K.20/45/21, 10/700 s voltage wave shape) 5/320 s (F CC Part 68, 9/720 s voltage wave shape) 10/560 s (FCC Part 68, 10/560 s voltage wave shape) 10/1000 s (Telcordia GR-1089-CORE, 10/1000 s voltage wave shape) Non-repetitive peak on-state current (see Notes 1 and 2) 20 ms (50 Hz) full sine wave 16.7 ms (60 Hz) full sine wave 0.2 s 50 Hz/60 Hz a.c. 2 s 50 Hz/60 Hz a.c. 1000 s 50 Hz/60 Hz a.c. Initial rate of rise of current (2/10 waveshape) Junction temperature Storage temperature range NOTES: 1. Initially the device must be in thermal equilibrium with TJ = 25 C. 2. The surge may be repeated after the device returns to its initial conditions. 45 50 21 7 2 450 -40 to +150 -65 to +150 500 400 200 150 150 125 100 `4015 `4030 `4040 Symbol VDRM Value 8 15 25 Unit V
ITSP
A
ITSM
A
di/dt TJ Tstg
A/s C C
Electrical Characteristics, TA = 25 C (Unless Otherwise Noted)
Parameter IDRM Repetitive peak offstate current Breakover voltage VD = VDRM `4015 `4030 `4040 `4015 `4030 `4040 Test Conditions Min Typ Max 5 15 30 40 33 57 74 0.8 3 `4015 `4030 `4040 50 Unit A
V(BO)
di/dt = 0.8 A/ms dv/dt 1000 V/s, Linear voltage ramp, Maximum ramp value = 500 V di/dt = 12 A/s, Linear current ramp, Maximum ramp value = 10 A di/dt = 0.8 A/ms I T = 5 A, t w = 100 s VD = 6 V VD = 13 V VD = 22 V I T = 5 A, di/dt = -/+30 mA/ms
V
V(BO)
Impulse breakover voltage Breakover current On-state voltage
V
I(BO) VT
A V
ID IH
Off-state current Holding current
2
A mA
AUGUST 1999 - REVISED FEBRUARY 2005 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.
TISP40xxH1BJ VLV Overvoltage Protector Series
Electrical Characteristics, TA = 25 C (Unless Otherwise Noted) (Continued)
Parameter Test Conditions f = 1 MHz, V d = 1 V rms, VD = 0 `4015 `4030 `4040 `4015 `4030 `4040 `4015 `4030 `4040 Min Typ 78 62 59 70 55 52 65 50 47 Max 100 81 77 90 72 68 85 65 61 Unit
f = 1 MHz, V d = 1 V rms, VD = 1 V Coff Off-state capacitance f = 1 MHz, V d = 1 V rms, VD = 2 V
pF
Thermal Characteristics
Parameter Test Conditions EIA/JESD51-3 PCB, IT = ITSM(1000) , TA = 25 C, (see Note 3) 265 mm x 210 mm populated line card, 4-layer PCB, IT = ITSM(1000) ,TA = 25 C 52 Min Typ Max 115 C/W Unit
RJA
Junction to free air thermal resistance
NOTE
3: EIA/JESD51-2 environment and PCB has standard footprint dimensions connected with 5 A rated printed wiring track widths.
AUGUST 1999 - REVISED FEBRUARY 2005 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.
TISP40xxH1BJ VLV Overvoltage Protector Series
Parameter Measurement Information
+i ITSP Quadrant I Switching Characteristic
ITSM
V(BO)
IH IDRM -v V DRM IDRM IH VD ID ID VD V DRM +v I(BO)
I(BO)
V(BO)
ITSM I Quadrant III Switching Characteristic ITSP -i
PM4AC
Figure 1. Voltage-Current Characteristic for T and R Terminals All Measurements are Referenced to the R Terminal
AUGUST 1999 - REVISED FEBRUARY 2005 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.
TISP40xxH1BJ VLV Overvoltage Protector Series
Typical Characteristics
CAPACITANCE vs OFF-STATE VOLTAGE
80 70 60 Coff - Capacitance - pF 50
TC4H1AE
'4015
40 '4030
30 '4040 TJ = 25 C Vd = 1 Vrms 20 0.01 0.02 0.05 0.1 0.2 0.5 1 2 3 5 VD - Off-state Voltage - V 10 20 30
Figure 2.
AUGUST 1999 - REVISED FEBRUARY 2005 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.
TISP40xxH1BJ VLV Overvoltage Protector Series
Rating and Thermal Information
NON-REPETITIVE PEAK ON-STATE CURRENT vs CURRENT DURATION
ITSM(t) - Non-Repetitive Peak On-State Current - A 60 50 40 30 20 15 10 8 7 6 5 4 3 2 1.5 0.01 0.1 1 10 100 1000
TI4MAJ
VGEN = 600 Vrms, 50/60 Hz RGEN = 1.4*VGEN /ITSM(t) EIA/JESD51-2 ENVIRONMENT EIA/JESD51-3 PCB TA = 25 C
t - Current Duration - s
Figure 3.
AUGUST 1999 - REVISED FEBRUARY 2005 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.
TISP40xxH1BJ VLV Overvoltage Protector Series
APPLICATIONS INFORMATION
Transformer Protection
The inductance of a transformer winding reduces considerably when the magnetic core material saturates. Saturation occurs when the magnetizing current through the winding inductance exceeds a certain value. It should be noted that this is a different current to the transformed current component from primary to secondary. The standard inductance-current relationship is:
di E = - L ---dt
where: L = unsaturated inductance value in H di = current change in A dt = time period in s for current change di E = winding voltage in V
((
Rearranging this equation and working large changes to saturation gives the useful circuit relationship of:
E x t = L x i
A transformer winding volt-second value for saturation gives the designer an idea of circuit operation under overvoltage conditions. The volt-second value is not normally quoted, but most manufacturers should provide it on request. A 50 Vs winding will support rectangular voltage pulses of 50 V for 1 s, 25 V for 2 s, 1 V for 50 s and so on. Once the transformer saturates, primary to secondary coupling will be lost and the winding resistance, RW, shunts the overvoltage protector, Th1 - see Figure 4. This saturated condition is a concern for long duration impulses and a.c. fault conditions because the current capability of the winding wire may be exceeded. For example, if the on-state voltage of the protector is 1 V and the winding resistance is 0.2 , the winding would bypass a current of 1/0.2 = 5 A, even through the protector was in the low voltage condition. T1 T1
UNSATURATED Th1 L SATURATED Th1 RW
AI4XAO
Figure 4. Transformer Saturation
Figure 5 shows a generic protection arrangement. Resistors R1 and R2, together with the overcurrent protection, prevent excessive winding current flow under a.c. conditions. Normally these resistors would only be needed for special cases, e.g. some T1/E1 designs. Alternatively, a split winding could be used with a single resistor connecting the windings. This resistor could be by-passed by a small capacitor to reduce signal attenuation. OVERAI4XAN CURRENT PROTECT ION R1 T1
LINE Th1 SIGNAL
R2
Figure 5. Transformer Winding Protection
Overcurrent protection upstream from the overvoltage protector can be fuse, PTC or thick film resistor based. For very high frequency circuits, fuse inductance due to spiral wound elements may need to be evaluated.
TISP(R) Device Voltage Selection
Normally, the working voltage value of the protector, VDRM, would be chosen to be just greater than the peak signal amplitude over the equipment temperature range. This would give the lowest possible protection voltage, V(BO). This would minimize the peak voltage applied to the transformer winding and increase the time to core saturation. In high frequency circuits, there are two further considerations. Low voltage protectors have a higher capacitance than high voltage protectors.
AUGUST 1999 - REVISED FEBRUARY 2005 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.
TISP40xxH1BJ VLV Overvoltage Protector Series
TISP(R) Device Voltage Selection (Continued)
So a higher voltage protector might be chosen specifically to reduce the protector capacitive effects on the signal. Low energy short duration spikes will be clipped by the protector. This will extend the spike duration and the data loss time. A higher protector voltage will reduce the data loss time. Generally, this will not be a significant factor for inter-conductor protection. However, clipping is significant for protection to ground, where there is continuous low-level a.c. common mode induction. In some cases the induced a.c. voltage can be over 10 V. Repetitive clipping at the induced a.c. peaks by the protector would cause severe data corruption. The expected a.c. voltage induced should be added to the maximum signal level for setting the protector VDRM value.
2-Wire Digital Systems
Typical systems using a single twisted pair connection are: Integrated Services Digital Network (ISDN) and Pair Gain. Signal level protection at the transformer winding is given by protectors Th3 and Th5. Typically these could be TISP4015H1 type devices with a 15 V voltage protection level.
LINE SIGNAL T1 Th1 Th3 C1 Th2 OVERCURRENT PROTECTION OVERCURRENT PROTECTION Th4 C2 Th5 T2 SIGNAL
TRANSFORMER COUPLED TWO-WIRE INTERFACE DC FEED DC SUPPLY
AI4XAL
Figure 6. 2-Wire System
Two line protection circuits are given; one referenced to ground using Th1 and Th2 (left) and the other inter-wire using protector Th4 (right) see Figure 6. For ISDN circuits compliant to ETSI ETR 080:1993, ranges 1 and 2 can be protected by the following device types: TISP4095M3, TISP4095H3, TISP3095H3 (combines Th1 and Th2) and TISP7095H3 (combines Th1, Th2 and Th4). Ranges 4 through 5 can be protected by: TISP4145M3, TISP4145H3, TISP3145H3 (combines Th1 and Th2) and TISP7145H3 (combines Th1, Th2 and Th4). Device surge requirement, H or M, will be set by the overcurrent protection components and the standards complied with. Protection of just the d.c. feed to ETSI ranges is covered in the TISP5xxxH3 data sheet. When loop test voltages exceed the normal d.c. feed levels, higher voltage protectors need to be selected. For two terminal protectors, for levels up to 190 V (135 V rms) the TISP4250, H3 or M3, can be used and for 210 V (150 V rms) the TISP4290, H3 or M3, can be used. In Pair Gain systems, the protector VDRM is normally set by the d.c. feed value. The following series of devices have a 160 V working voltage at 25 C: TISP4220M3, TISP4220H3, TISP3210H3 (combines Th1 and Th2) and TISP7210H3 (combines Th1, Th2 and Th4). These devices can be used on 150 V d.c. feed voltages down to an ambient temperature of -25 C. Where the subscriber equipment may be exposed to POTS (Plain Old Telephone Service) voltage levels, protector Th4 needs a higher working voltage of about 275 V. Suitable device types are: TISP4350M3, TISP4350H3, TISP3350H3 (combines Th1 and Th2) and TISP7350H3 (combines Th1, Th2 and Th4). The overcurrent protection for the overvoltage protector can be fuse, PTC or thick film resistor based. Its a.c. limiting capability should be less than the ratings of the intended overvoltage protector. Equipment complying with the year 2000 international K.20, K.21 and K.45 recommendations from the ITU-T, may be required to demonstrate protection coordination with the intended primary protector. Without adding series resistance, a simple series fuse overcurrent protection is likely to fail the equipment for this part of the recommendation. If the d.c. feed consists of equal magnitude positive and negative voltage supplies, appropriately connected TISP5xxxH3 unidirectional protectors could replace Th1 and Th2.
4-Wire Digital Systems
A typical system using a two twisted pair connection is the High-bit-rate Digital Subscriber Line (HDSL) and the "S" interface of ISDN. Figure 7 shows a generic two line system. HDSL tends to have ground referenced protection at both ends of the lines (Th1, Th2, Th3 and Th4). The ISDN "S" interface is often inside the premises and simple inter-wire protection is used at the terminating adaptor (Th7 and Th8). In all
AUGUST 1999 - REVISED FEBRUARY 2005 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.
TISP40xxH1BJ VLV Overvoltage Protector Series
4-Wire Digital Systems
LINE 1 SIGNAL T1 Th1 Th5 Th2 OVERCURRENT PROTECTION OVERCURRENT PROTECTION Th7 Th9 T3 SIGNAL
DC FEED LINE 2 SIGNAL T2 Th3 Th6 Th4 OVERCURRENT PROTECTION OVERCURRENT PROTECTION Th8
DC SUPPLY T4 SIGNAL
Th10
TRANSFORMER COUPLED FOUR-WIRE INTERFACE
AI4XAM
Figure 7. 4-Wire System
cases, signal protection, Th5, Th6, Th9 and Th10, can be TISP4015H1 type devices with a 15 V voltage protection level. For an HDSL d.c. feed voltage of 180 V or less and operation down to an ambient of -25 C, the following Th1, Th2, Th3 and Th4 protectors are suitable: TISP4250M3 or TISP4250H3, TISP3250H3 (combines Th1 and Th2 or Th3 and Th4) and TISP7250H3 (combines Th1, Th2 and Th7 or Th3, Th4 and Th8). Possible overcurrent protection components are covered in the 2-wire digital systems clause. For ISDN interfaces powered with 40 V (ETSI, ETS 300 012 1992) the following Th1, Th2, Th3 and Th4 protectors are suitable: TISP4070M3 or TISP4070H3 or TISP4070L3, TISP3070F3 or TISP3070H3 (combines Th1 and Th2 or Th3 and Th4) and TISP7070F3 or TISP7070H3 (combines Th1, Th2 and Th7 or Th3, Th4 and Th8). At the terminating adaptor, the Th7 and Th8 protectors do not "see" the d.c. feed voltage and should be selected to not clip the maximum signal level. Generally, the TISP40xxH1 series will be suitable. Internal ISDN lines are not exposed to high stress levels and the chances of a.c. power intrusion are low (ETSI EN 300 386-2 1997). Accordingly, the equipment port protection needs are at a lower level than ports connected to outside lines.
Home Phone Networking
Using the existing house telephone wiring, home phone networking systems place the local network traffic in a high band above the POTS and ADSL (Asymmetrical Digital Subscriber Line) spectrum. Local network rates are 1 Mbps or more. To reject noise and harmonics, an in-line protection and 5 MHz to 10 MHz bandpass filter module is used for the equipment. These modules are available from magnetic component manufacturers (e.g. Bel Fuse Inc.) A typical circuit for the telephone line magnetics module is shown in Figure 8. Transformer T1 isolates the equipment from the house wiring. The isolated winding output is voltage limited by a very low-voltage protector, Th1. With a differential voltage of about 12 V peak to peak, the TISP4015H1 could be used for Th1. After filtering, connection is made to the differential transceiver of the processing IC. TIP T1 FILTER
HRTRX+
Th1 C1
HRTRXAI4XAP
PROTECTION
RING
Figure 8. Home Phone Networking Isolation/filter/protection Circuit
"TISP" is a trademark of Bourns, Ltd., a Bourns Company, and is Registered in U.S. Patent and Trademark Office. "Bourns" is a registered trademark of Bourns, Inc. in the U.S. and other countries.
AUGUST 1999 - REVISED FEBRUARY 2005 Specifications are subject to change without notice. Customers should verify actual device performance in their specific applications.


▲Up To Search▲   

 
Price & Availability of TISP4015H1BJR-S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X